Drive-Cliq Interface - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

10.4.2.2

DRIVE-CLiQ interface

Table 10- 18 DRIVE-CLiQ interface
Connector
type
Current consumption, maximum 0.25 A
The blanking cover for the DRIVE-CLiQ port to secure the degree of protection IP 67 is not included in
the scope of delivery.
Blanking covers (6 units), article number: 6SL3066-4CA01-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used for connections. The maximum
cable length is 100 m for MOTION-CONNECT 500, and 75 m for MOTION-CONNECT
800PLUS cables.
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
Encoder system connection
10.4 Sensor Module External SME25
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground