Encoder system connection
10.3 Sensor Module External SME20
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is
bare, unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm.
10.3.7
Technical data
Table 10- 17 Technical data
6SL3055-0AA00-5EA3
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
)
encoder
PE/ground connection
Weight
Degree of protection
254
Unit
Value
V
24 (20.4 ... 28.8)
DC
A
≤ 0.15
DC
A
≤ 0.25
DC
W
≤ 4
V
5
DC
A
0.35
DC
kHz
≤ 500
At the housing with M4 / 1.8 Nm screw
kg
0.31
IP67
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7