Technical Data - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Encoder system connection
10.3 Sensor Module External SME20
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is
bare, unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm.
10.3.7

Technical data

Table 10- 17 Technical data
6SL3055-0AA00-5EA3
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
)
encoder
PE/ground connection
Weight
Degree of protection
254
Unit
Value
V
24 (20.4 ... 28.8)
DC
A
≤ 0.15
DC
A
≤ 0.25
DC
W
≤ 4
V
5
DC
A
0.35
DC
kHz
≤ 500
At the housing with M4 / 1.8 Nm screw
kg
0.31
IP67
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7

Advertisement

Table of Contents
loading