DC link components
7.2 Braking Module Booksize
7.2.5
Meaning of the LEDs
Table 7- 10
Meaning of the LEDs on the Braking Module Booksize
Status
RDY
DC LINK
Off
Off
Green
Off
Green flashing
light
Red
Off
172
Description, cause
Electronics power supply is missing or outside the per-
missible tolerance range.
Component not active or has been deactivated via the
terminal.
Component is ready for operation.
Electronics power supply is missing or outside the per-
missible tolerance range.
Component not active.
Component active (DC link discharge via braking resis-
tor in progress).
Approval missing (input terminal)
Overtemperature
Overcurrent trip
I
t-monitoring activated
2
Ground fault/short circuit
Comment:
In the event of overtemperature, the error cannot be
acknowledged until after a cooling phase.
Remedy
–
–
–
Diagnose fault (via output
terminals) and acknowledge
it (via input terminal)
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7