Additional system components
9.1 Terminal Module TM54F
9.1.3.2

X500/X501 DRIVE-CLiQ interfaces

Table 9- 2
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article number: 6SL3066-4CA00-0AA0
Note
Maximum cable length
The maximum DRIVE-CLiQ cable length is 100 m.
9.1.3.3

X514 power supply for digital outputs and sensors

Table 9- 3
X514: Power supply
Terminal
+
+
M1
M1
Type: Screw terminal 3 (Page 288)
Including the current consumption for the digital outputs and to supply the sensor
1)
The maximum cable length that can be connected is 30 m.
Note
The two "+" and "M1" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
192
X500/X501: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Designation
Power supply
Power supply
Electronics ground
Electronics ground
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical specifications
Voltage: 24 VDC (20.4 ... 28.8 V)
Current consumption: Maximum 4 A
Maximum current through the jumper in the connector:
20 A (15 A according to UL/CSA)
Manual, 11/2017, 6SL3097-4AV00-0BP7