Additional system components
9.1 Terminal Module TM54F
9.1.3.2

X500/X501 DRIVE-CLiQ interfaces

Table 9- 2
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article number: 6SL3066-4CA00-0AA0
9.1.3.3

X514 power supply for digital outputs and sensors

Table 9- 3
Terminals for the power supply X514
Terminal
+
+
M1
M1
Including the current consumption for the digital outputs and to supply the sensor
1)
The maximum cable length that can be connected is 10 m.
Note
The two "+" and "M1" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
206
X500/X501: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Designation
Power supply
Power supply
Electronics ground
Electronics ground
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: max. 4 A
Max. current via jumper in connector: 20 A (15 A ac-
cording to UL/CSA)
Type: Screw terminal 3 (Page 307)
Max. connectable cross-section: 2.5 mm²
Tightening torque: 0.4 ... 0.5 Nm