Interface Description; X524 Electronics Power Supply; X500/X501 Drive-Cliq Interfaces - Siemens SINAMICS G130 Operating Instructions Manual

Terminal module 150 (tm150)
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Electrical installation

4.2 Interface description

4.2
Interface description
4.2.1

X524 electronics power supply

Table 4- 1
Terminal strip for the electronic power supply X524
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm²
Note
Looping through the supply voltage
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ node.
4.2.2

X500/X501 DRIVE-CLiQ interfaces

Table 4- 2
DRIVE-CLiQ interface X500/X501
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Order number: 6SL3066-4CA00-0AA0
20
Designation
Electronic power supply
Electronic power supply
Electronic ground
Electronic ground
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
Voltage: 24 VDC (20.4 V – 28.8 V)
Current consumption (max./typ.): 0.5 A / 0.1 A
Max. current via jumper in connector: 20 A (15 A according
to UL/CSA)
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Operating Instructions, 04/2014, A5E03758735A