Install The Load Sense Hose - Raven SmarTrax Installation Manual

For agco rt-a series, massey ferguson 64xx/74xx/76xx series and challenger mt5x5b series
Hide thumbs Also See for SmarTrax:
Table of Contents

Advertisement

Chapter 3
Pressure Transducer Assembly Installed
FIGURE 17.
Disconnect the pressure line from the machine's priority valve.
6.
Install the transducer assembly on the open port of the priority valve.
7.
Connect the pressure line to the opposite end of the transducer assembly.
8.

Install the Load Sense Hose

Shuttle Valve Assembly
FIGURE 18.
Assembly the shuttle valve assembly as shown in Figure 17 above.
1.
Install the -6 JIC (F) to 6- SAE O-ring (M) straight adapter fitting (P/N 333-0012-086) and -6 SAE O-
a.
ring (M) plug fitting (P/N 333-0012-104) into the end hex ports of the shuttle valve (P/N 334-0003-016).
24
AGCO RT-A Series, Massey Ferguson 64XX/74XX/76XX Series, Challenger MT5X5B Series SmarTrax™ Installation Manual
-6 JIC 5 PSI Check
Valve
(P/N 333-0003-078)
-6 JIC (M) to -6 SAE
O-Ring (M) Straight
Adapter Fitting
(P/N 333-0012-045)
Shuttle Valve
(P/N 334--0003-016)
-6 JIC (F) to -6 SAE O-Ring (M)
Straight Adapter Fitting
(P/N 333-0012-086)
-6 SAE O-Ring (M) Plug Fitting
(P/N 333-0012-104)