Install The Load Sense Hose - Raven AutoBoom Installation Manual

For spra-coupe 7x60
Hide thumbs Also See for AutoBoom:
Table of Contents

Advertisement

Chapter 3

Install the Load Sense Hose

Fittings Installed on the Logic Valve
FIGURE 12.
333-0012-176
333-0012-297
Install the fittings in the appropriate ports of the logic valve (P/N 334-0003-075) as illustrated above.
1.
Tighten all fittings installed on the logic valve.
2.
Locate the machine's auxiliary pump in the engine compartment.
3.
Disconnect the machine's priority valve load sense hose form the auxiliary pump.
4.
Install Port 1 of the logic valve in the port from which the priority valve load sense hose was disconnected.
5.
Connect the machine's priority valve load sense hose that was previously disconnected to Port 2 of the logic
6.
valve.
Install one end of the supplied hydraulic hose (P/N 214-1000-639) to Port 3 of the logic valve.
7.
Connect the other end of the supplied hydraulic hose to Port LSP on the AutoBoom valve.
8.
18
Spra-Coupe 7X60 (2010 & Newer) AutoBoom® Installation Manual
333-0012-297
333-0012-298
333-0012-176

Advertisement

Table of Contents
loading

Table of Contents