Chapter 3
SmarTrax Valve Installed
FIGURE 7.
Install the valve mounting on the machine's hydraulic valve.
2.
•
If the valve is being installed in position 2, use two M8 x 1.25 x 25 mm metric hex bolts (P/N 311-0070-001)
and two 5/16" flat washers (P/N 313-2300-011) to mount the valve.
•
If the valve is being installed in position 3, use two 5/16"-18 x 1-1/4" hex bolts (P/N 311-0052-106), two 5/16"
flat washers (P/N 313-2300-011), and two 5/16"-18 UNC flanged lock nuts (P/N 312-1001-169) to mount the
valve.
Install the Left and Right Steering Hoses
Note:
Mark the machine's steering hoses to ensure they are reinstalled in the correct ports later in the
procedure.
Steering Orbital Location
FIGURE 8.
Raise the machine's hood and remove the left panel (if equipped) to locate the steering orbital.
1.
Locate and disconnect the left and right steering hoses connected to the steering orbital.
2.
18
AGCO RT-A Series, Massey Ferguson 64XX/74XX/76XX Series, Challenger MT5X5B Series SmarTrax™ Installation Manual