Install the Load Sense Hose
Note:
It may be necessary to install a -6 JIC M/F 90° elbow fitting (P/N 333-0012-042) on the SmarTrax
valve in order to complete the connection.
Load Sense Connections
FIGURE 13.
Locate the load sense port on the left side of the SCV at the rear of the tractor.
1.
Remove the existing load sense hose from the machine's SCV.
2.
Swivel Run Tee Connections
FIGURE 14.
Original Machine Hose
Original Machine Hose
To SmarTrax Valve
Install the female end of the supplied hydraulic hose (P/N 214-1000-904) onto the open load sense port.
3.
Install a -4 ORFS swivel run tee (P/N 333-0012-022) onto the male end of the supplied hydraulic hose (P/N
4.
214-1000-904).
Install the machine's load sense hose onto the -4 ORFS swivel run tee.
5.
Install the straight end of the supplied hydraulic hose (P/N 214-1000-892) on the remaining branch of the -4
6.
ORFS swivel run tee.
Manual No. 016-5032-008 Rev. B
Load Sense
Port
Original Hose
Disconnected
from Load
Sense Port
Hydraulic System Installation
To LS Port on SCV
21