After the appliance is started successfully, the Power-on and the POST complete
(see Figure 5 on page 5) are lit. If a failure occurs during start up, refer to the
troubleshooting chapter in the Network Attached Storage 200 User's Reference to
identify and resolve the problem.
v Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
Note: For translations of this safety notice, refer to Safety Information.

Stopping the appliance

There are also several ways to shut down the appliance:
v Press the Power control button on the front of the appliance. This starts an
v Press and hold the Power control button for more than 4 seconds to cause an
v Disconnect the appliance power cords from the electrical outlets to shut off all

Using the Configuration/Setup Utility program

This section provides the instructions needed to start the Configuration/Setup Utility
program and descriptions of the menu choices available.
94
Models 200 and 225 Service Guide
200 for at least 15 minutes after the initial system start. This notice applies
only to the first time the Network Attached Storage 200 is started.
orderly shutdown of the operating system, if this feature is supported by your
operating system, and places the appliance in standby mode.
Note: After turning off the appliance, wait at least 5 seconds before you press
the Power control button to power the appliance on again.
immediate shutdown of the appliance and place the appliance in standby mode.
You can use this feature if the operating system ceases to function.
power to the appliance.
Note: Wait about 15 seconds after disconnecting the power cords for your
system to stop running. Watch for the Power-on on the operator
information panel to stop blinking.