IBM TotalStorage 200 Service Manual page 50

Network attached storage
Hide thumbs Also See for TotalStorage 200:
Table of Contents

Advertisement

Table 8. POST error codes (continued)
Error
Meaning
Code/Symptom
5962
IDE CD-ROM configuration
error
8603
Pointing Device error
00019501
Processor 1 is not functioning Suspected part:
00019502
Processor 2 is not functioning Suspected part:
00019701
Processor 1 failed BIST
00019702
Processor 2 failed BIST
00180100
No room for PCI option ROM Suspected part:
00180200
No more I/O space available
for PCI adapter
34
Models 200 and 225 Service Guide
Suspected Part/Suggested Action
Suspected part:
1. CD-ROM Drive
2. CD-ROM Power Cable
3. IDE Cable
4. System Board
5. Battery
Suggested action:
Run Configuration/Setup
Suspected part:
1. Pointing Device
2. System Board
1. VRM 1, VRM 2
2. Processor 1
3. Processor Board
4. System Board
Suggested action: Check VRM and processor LEDs
1. VRM 2
2. Processor 2
3. Processor Board
4. System Board
Suggested action: Check VRM and processor LEDs
Suspected part:
1. Processor 1
2. Processor/PCI Board
3. System Board
Suspected part:
1. Processor 2
2. Processor/PCI Board
3. System Board
1. Failing Adapter
2. System Board
Suggested action:
Run Configuration/Setup
Suspected part:
1. Failing Adapter
2. System Board
Suggested action:
Run Configuration/Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Totalstorage 225

Table of Contents