IBM TotalStorage 200 Service Manual page 40

Network attached storage
Hide thumbs Also See for TotalStorage 200:
Table of Contents

Advertisement

Table 5. Diagnostic error codes (continued)
Error Code
Meaning
180-XXX-004
Failed Processor Board LED
test
180-XXX-005
Failed SCSI Backplane LED
test
180-XXX-006
Memory Board LED test
201-XXX-0NN
Failed Memory test
201-XXX-999
Multiple DIMM failure; see
error text for failing DIMMs
202-XXX-001
Failed System Cache test
202-XXX-002
Failed System Cache test
206-XXX-000
Failed Diskette Drive test
215-XXX-000
Failed IDE CD-ROM test
217-XXX-000
Failed BIOS Hard Disk test
Note: If RAID is configured,
the hard disk number refers
to the RAID logical array.
217-XXX-001
Failed BIOS Hard Disk test
Note: If RAID is configured,
the hard disk number refers
to the RAID logical array.
217-XXX-002
Failed BIOS Hard Disk test.
Note: If RAID is configured,
the hard disk number refers
to the RAID logical array
24
Models 200 and 225 Service Guide
Suspected Part/Suggested Actions
Suspected part:
1. Processor/PCI Board
2. System Board
Suspected part:
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
Suspected part:
1. Memory
2. Processor/PCI Board
3. System Board
Suspected part:
1. DIMM Location DIMM1 - DIMM4 where NN can be a value
from 01 to 04. 01 = DIMM2, 02 = DIMM1, 03 = DIMM4, 04 =
DIMM3
2. System Board
Suspected part: System Board
Suspected part:
1. VRM 1
2. Microprocessor 1
Suspected part:
1. VRM 2
2. Microprocessor 2
Suspected part:
1. Cable
2. Diskette Drive
3. System Board
Suspected part:
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
Suspected part: Hard Disk 1
Suspected part: Hard Disk 2
Suspected part: Hard Disk 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Totalstorage 225

Table of Contents