System Specifications

Table 19 System specifications
a
Transfer relay rating (A
)
b
Transfer time (ms
)
   Shore to inverter:
   Inverter to shore:
Transfer voltage (V)
   Shore to inverter:
   Inverter to shore:
Cooling
Over Voltage Category [OVC]
Safety Protective Class
a
 Circuit breakers shall not carry more than 80% of their current rating continuously.
b
 To change the AC Transfer time (mode), see Adjusting Feature Settings in Configuration Mode on page
55.
975-0821-01-01
Freedom XC 2000 (230VAC)
30AV
<20 ms
<20 ms with a 20-s delay
<180 V V
and >280 V V
<270 V V
and >190 V V
Fan, activated by any of the
following:
High internal temperature
High AC output power
Input AC: OVC III
Output AC: OVC II
Class I
Table 20 DC input for inverting
Operating voltage range
Maximum non-operating voltage 25.2 V Z
Nominal voltage
Nominal current at full load
Table 21 AC output for inverting
Output voltage options
a
Continuous power
Continuous current
Surge power (5 s)
b
Frequency
Wave shape
Peak efficiency
Full load efficiency
a
 Power derates to 85% when output voltage is set to 220 VV.
b
 To set the AC Frequency, see Adjusting Feature Settings in Configuration Mode on page 55.
System Specifications
Freedom XC 2000 (230VAC)
10–17.0 V Z
12.0 V Z
192 A Z
Freedom XC 2000 (230VAC)
220, 230, 240VV
2000 W @ 40 °C
8.7 A V
4000 W
50 (or 60) Hz
True Sine Wave
93%
> 90%
87

Hide quick links: