Operating in Grid Mode
Figure 20 Equalize charging
66
Custom Battery Settings Menu
NOTICE
REVERSE POLARITY
To avoid damaging your batteries during charging or
equalization, consult your battery manufacturer and associated
documentation before setting a custom battery type.
Failure to follow these instructions can result in equipment
damage.
Custom battery type can be selected by the setting number 20
(see Custom Battery Settings Menu on page 66). After the custom
battery is selected, you can then adjust the value of custom
absorption (setting number 22) and custom float (setting number
23) accordingly.
Freedom XC 2000 (230VAC) Owner's Guide