Operating
Battery
Condition
Voltage
Low
Voltage
< LBCO
Shutdown
Instant Low
Voltage
< 9.0 V
Shutdown
975-0821-01-01
Comment
The buzzer sounds a single 1 s
low battery alarm beep and the
LCD screen shows error code
E01. After LBCO Shutdown
delay timer runs out, the unit
shuts down inverter output. The
buzzer stops beeping and the
LCD screen shows error code
E01.
After 2 s below the limit, the unit
shuts down inverter output
completely. LCD screen turns
off completely.
Operating During Transition Between Grid Mode and Battery Mode
Operating
Battery
Condition
Voltage
High
Voltage
17.0 V
Shutdown
Comment
The display shows error code
E02 alternating with the battery
voltage. The red status LED
turns on. 
NOTE: Although the Freedom
XC incorporates over-voltage
protection, it can still be
damaged if input voltage
exceeds 18.0 VZ.