System Specifications - Xantrex Freedom X 1200 Owner's Manual

120v sine wave inverter
Table of Contents

Advertisement

System Specifications

Table 17 System specifications
a
Transfer relay rating (A
)
Transfer time (milliseconds
   Shore to inverter:
   Inverter to shore:
Transfer voltage (V)
   Shore to inverter:
   Inverter to shore:
Cooling
a
 Circuit breakers shall not carry more than 80% of their UL current rating continuously.
b
 To change the AC Transfer time (mode), see Adjusting Feature Settings in Configuration Mode on page
1.
975-0767-01-01
Freedom X 1200
30A surge (24A continuous)
b
)
<20 milliseconds
<20 milliseconds with a 20-
second delay
<95 V and >135 V
<130 V and >100 V
Fan, activated by any of the
following:
   High internal temperature
   High AC output power
Table 18 DC input for inverting
Operating voltage range
Maximum non-operating voltage 0–24 VDC
Nominal voltage
Nominal current at full load
a
To set LBCO, see Adjusting Feature Settings in Configuration Mode on page 1.
System Specifications
Freedom X 1200
a
LBCO voltage
–16.5 VDC
12.0 VDC
116 ADC
95