Download Print this page

Troubleshooting; Specifications - Xantrex 784-9115-01 Installation Manual

Hide thumbs Also See for 784-9115-01:

Advertisement

Troubleshooting

ELECTRICAL SHOCK HAZARD
If the in-line fuse on the 10AWG positive (+) battery cable blows, replace with a 30A/32V green ATC
blade fuse.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
NOTE: To obtain service go to Contact Information on page 1.
Problem
Battery does not get charged
even when sunlight is
present.

Specifications

NOTE: Specifications are subject to change without prior notice.
115W Solar Max Flex Panel
Part number
Dimensions
Unit weight
Cell Type
Maximum power at STC*
Maximum power voltage
Maximum power current
Open circuit voltage
Short circuit current
Maximum system voltage
Safety
* Standard Test Conditions(STC): Irradiance: 1000W/m2, CellTemperature: 25°C, Air Mass: 1.5
15
WARNING
Possible Cause
Solar panel is partially shaded
or there is insufficient sunlight.
Loose or no DC cable
connections.
Fuse is blown.
784-9115-01
37.5in x 28.4in x 0.08in (953mm x 722mm x 2mm)
6.0 lbs.(2.7 kg)
Monocrystalline PERC
115 W
22.1 V
5.2 A
27.4 V 
5.6 A
600 VDC
Class III PV Module
Solution
Move the vehicle or vessel so the whole
solar panel is exposed to direct sunlight.
Connect DC cables to the battery and
solar panel and tighten terminal
connections.
Replace the blown fuse with a 30A/32V
green ATC blade fuse.
975-1029-01-01 Rev E
February 2024

Advertisement

loading

This manual is also suitable for:

784-9115s-01784-9220-01784-0330