Default Settings - Xantrex Freedom XC 2000 Owner's Manual

Inverter/charger 230vac
Hide thumbs Also See for Freedom XC 2000:
Table of Contents

Advertisement

Default Settings

Default Settings
Table 1 lists the default settings for the Freedom XC system.
You may record your settings in the right-hand column after you have configured the Freedom XC.
Table 1 Freedom XC Default Values
Program
01
Inverter ignition control
02
Low battery cutoff (LBCO) voltage
03
LBCO shutdown delay timer
04
LBCO recovery voltage
05
Power save time
06
Load sensing
07
Inverter output frequency
08
Inverter output voltage
09
Inverter power limit
10
Inverter power limit timer
11
Transfer mode
12
Utility AC under-voltage level
13
Inverter fault recovery
8
Item
Default Setting
Off
10.5 VZ 10.5
300 s
13.1 VZ 13.1
25 h
Disabled
50 Hz
230 VV
2 kW
300 s
Appliance APL
180 VV
Manual
Setting
Off
300
25
dis
50
230
2
300
180
man
Freedom XC 2000 (230VAC) Owner's Guide