Troubleshooting Reference
Problem
No output voltage is shown in the LCD
screen but the green status LED for
Battery mode is illuminated.
No output voltage is shown in the LCD
screen and neither of the green status
LEDs (for Grid mode and Battery mode)
is illuminated.
80
Possible Cause
RCBO (when installed
downstream) has tripped or
supplementary breaker has
tripped.
Circuit breaker on the AC load
panel or AC output disconnect has
tripped.
Battery voltage is too low
(depending on setting, see
Maintaining the Freedom XC Unit
on page 72) to start inverting. LCD
screen may show DC voltage as
000.
AC shore power is not available or
out of operating range and the
inverter/charger is OFF.
AC shore power is not available
and the inverter/charger is OFF
due to a shutdown for more than
30 s.
Solution
Check load and reset the RCBO or supplementary
breaker.
Reset the circuit breaker or check the AC output
disconnect circuits.
Check DC connections and cable.
Recharge battery.
Check AC shore power.
Turn the inverter/charger ON.
Check AC shore power and battery voltage.
Turn the inverter/charger ON and look at the LCD
screen for any error code.
See "Problem" on the previous page.