Settings - Xantrex Freedom XC 2000 Owner's Manual

Inverter/charger 230vac
Hide thumbs Also See for Freedom XC 2000:
Table of Contents

Advertisement

Adjusting Feature Settings in Configuration Mode

Settings

Setting Name
Inverter Ignition Control
LBCO Voltage
LBCO Shutdown Delay
Timer
LBCO Recovery Voltage
Power Save Time
Power Save (Load
Sensing) Mode
56
Setting
Default
Range of
Number
Value
OFF
01
OFF
LOT
ATO
02
10.5
10.0 to 12.8
03
10
0 to 600
04
13.1
10.2 to 16.0
05
25
OFF, 1 to 25
ENA (enable),
06
dIs
DIS (disable)
Values
See Description of Ignition Control Features on page 42.
The voltage setting value can be adjusted by 0.1 increments. The
inverter is able to recover automatically at LBCO voltage + 2.0 V
(default).
When the range is from 1 to 20, the timer setting value can be
adjusted by 1-s increments. When the range is from 20 to 300, the
timer setting value can be adjusted by 10-s increments.
The range is from LBCO voltage + 0.2 to 32, adjusted by 0.1
increments. Selecting a higher value than the battery's actual fully-
charged voltage level will disable the auto-recovery feature. You
may manually reset the inverter/charger when the low battery cut
off event occurs.
The range is from 1 to 25, adjusted by 1-h increments. The next
setting after 25 is OFF.
When enabled, the inverter/charger's "no load" loss can be
reduced further when total load is less than 25 W.
Description
Freedom XC 2000 (230VAC) Owner's Guide