Operating In Grid Mode; Battery Charger Functions; Battery Types - Xantrex Freedom XC 2000 Owner's Manual

Inverter/charger 230vac
Hide thumbs Also See for Freedom XC 2000:
Table of Contents

Advertisement

Operating in Grid Mode

Operating in Grid Mode

Battery Charger Functions

When AC power is available, the Freedom XC can operate as a
12-VZ battery charger. Different battery types and chemistries
require different charging voltage levels. Not charging batteries at
the required levels can shorten battery life or damage the
batteries. The Freedom XC is configured at the factory to work
with the battery types recommended for inverter applications. If
the default settings do not work for your specific installation, you
can adjust the charge stage settings (as recommended by the
battery manufacturer) on the Custom (Battery) Settings menu
(see on page 62).
NOTE: This information is provided for guidance only. Variations
in battery chemistry and site-specific environmental
considerations mean that you should consult your system
designer or battery manufacturer for specific recommendations for
appropriate battery voltage and current settings.
62

Battery Types

The Freedom XC 2000 (230VAC) Inverter/Charger charges
flooded (or wet) lead-acid, Gel, AGM (absorbed glass mat),
custom, and lithium iron phosphate (LFP) batteries.
Flooded (or wet) batteries have removable battery caps for
n
refilling with distilled water and testing the electrolyte.
NOTE: Add distilled water in each cell until battery acid
reaches the level specified by the battery manufacturer. This
helps purge excessive gas from cells. Do not overfill. For a
battery without cell caps, carefully follow the battery
manufacturer's recharging instructions.
Gel batteries have the electrolyte in the form of a gel rather
n
than a liquid and do not require topping up. Gel batteries are
sealed and the battery caps are not removable.
AGM (Absorbed Glass Mat) batteries are similar to gel
n
batteries except that the electrolyte is absorbed into a
fiberglass matting.
Custom battery is configured by the dealer, factory, or
n
service center for battery types other than those listed
above.
Lithium iron phosphate (LFP) must only be selected with a
n
lithium iron phosphate battery module with a certified / listed
Battery Management System (BMS).
Freedom XC 2000 (230VAC) Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

817-2080-12

Table of Contents