Regulatory Approvals - Xantrex Freedom XC 2000 Owner's Manual

Inverter/charger 230vac
Hide thumbs Also See for Freedom XC 2000:
Table of Contents

Advertisement

Regulatory Approvals

Table 22 AC input for charging
Operating voltage range
Safe non-operating voltage
range
Full load maximum current
Nominal frequency
Power factor at full charge
Table 23 DC output for charging
Nominal voltage
Min battery voltage for charging
Max output voltage
Nominal output current
c
Charger current is rated to 14.4 V Z output only. The charger derates if a high Z output voltage is
selected.
88
Freedom XC 2000 (230VAC)
170–280 VV
up to 300 VV
5.6 A V
50 (or 60) Hz
> 98%
Freedom XC 2000 (230VAC)
12.0 V Z
0.0 V Z
17.0 V Z (custom battery type)
c
User selectable: 5 to 80A
Charger current derating
Efficiency at nominal output
Regulatory Approvals
Table 24 Regulatory approvals
Safety
EMC
Environmental
Freedom XC 2000 (230VAC) Owner's Guide
Freedom XC 2000 (230VAC)
May reduce charger current
depending on ambient
temperature.
≥91%
Freedom XC 2000 (230VAC)
Compliance with CE Marking:
Low Voltage Directive
(2014/35/EU)
For marine installations, use of
drip shield with product number
808-1050 is required.
Compliance with CE Marking:
Electromagnetic Compatibility
(EMC) Directive (2014/30/EU)
Compliance with CE Marking:
Restriction of Specific Hazardous
Substances (RoHS) Directive
(2011/65/EU and amendments)