6.3 Configuration via XML

Parameter
Frame length
Character delay time
Only in connection with the reader interfaces X21 and X22.
1)
Description of block commands
You can find a description of the block-specific commands in the respective block manuals:
• FB 45 for RF200, RF300
• RFID standard profile; standard function for RFID systems
• Ident profile and Ident blocks, standard function for Ident systems
6.3
Configuration via XML
This section is intended only for XML users.
Configuration of the communications module is not possible for pure XML work. However,
you can read diagnostic data from the communications modules via XML. You will find
detailed information on this in the manual "XML programming for SIMATIC Ident
(https://support.industry.siemens.com/cs/ww/en/view/109781631)".
6.4

Configuration via OPC UA

This section is intended only for OPC UA users.
Configuration of the communications module is not possible for pure OPC UA work. However,
you can read diagnostic data from the communications modules via OPC UA. You will find
detailed information on this in the manual "OPC UA for SIMATIC Ident
(https://support.industry.siemens.com/cs/ww/en/ps/14971/man)".
56
Parameter value
1...233 / 1...229
0...65535
Default value
Description
233
Entry of the frame length in bytes for the end
criterion "On receipt of fixed number of
characters".
15
Entry of the time [ms] that can elapse until a
frame end is recognized. Select the character
delay time dependent on the sending behavior
of your communication partner. Depending on
the data transmission speed, the character delay
time is limited to a minimum value.
Note that the ASCII driver also pauses between
two frames during transmission.