Electrical Specifications - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

Technical Details
3.4.
Aerotech configures each DR300 to fit the user's particular power requirements. The
possible input voltages are 115 VAC, 230 VAC, 100 VAC, and 208 VAC (refer to
Table 3-14). Each DR300 systems power specifications can be found on the power
specification tag located on the rear of the DR300 chassis (see following example).
Example:
WARNING
Table 3-14.
3-18
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DR300 Operation and Technical Manual

Electrical Specifications

115V~ 50/60Hz 5A
Hazardous voltage may be present.
Electrical Specifications
VAC IN RMS
# of Axis
2
115VAC
2
4
±10%
4
230VAC
2
±10%
4
100VAC
2
±10%
4
208VAC
2
±10%
4
Line Frequency:
Installation category: Overvoltage Category II
Equipment class:
Aerotech, Inc.
Max. AC Line
Bus Voltage
Input
5A
(40,60,80,160)
10A
160 (no Isolation
transformer)
10A
(40,60,80,160)
10A
160 (no Isolation
transformer)
5A
(40,60,80,160)
5A
(40,60,80,160)
5A
(40,60,80,160)
10A
(40,60,80,160)
5A
(40,60,80,160)
5A
(40,60,80,160)
50 Hz to 60 Hz
Class I (equipment with basic insulation/grounded)
Max. Watts Out
350
1000
700
2000
350
700
350
700
350
700
Version 1.5