Troubleshooting The Ds160 Series - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

Set Up
2.2.6.7.
A troubleshooting guide for the DS160 Series Servo Amplifier module is provided in
Table 2-12. A list of recommended spare parts for the DS160 Series Servo Amplifier
Module is shown in Table 2-13. Environmental and Power Stage Specifications are listed
below.
Table 2-10.
Operating Temp
Storage Temp
Humidity
Table 2-11.
Short Circuit Trip
Typical input/output
impedance
DC bus high voltage
trip
Typical
efficiency
2-20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DR300 Operation and Technical Manual

Troubleshooting the DS160 Series

DS160 Series Environmental Specifications
Unit
Value
°C
50 (max) –
0 (min)
°C
+85 (max) –
-30 (min)
%
10 – 90
Power Stage Specifications
Unit
Value
Amps
40
(min)
Ohms
.3
(max)
VDC
205
(min)
switching
%
93
(min)
Aerotech, Inc.
Comment
Ambient temp of the servo module heatsink,
not the enclosure
Shelf storage only, not stand-by use
Non-condensing
Pin
Comment
J1-26, 30
Requires power-down reset. Max
may be as high as 60 amps.
J1-26, 28,
From bus connection (28 or 32)
30, 32
to motor connection (26 or 30)
J1-28, 32
Requires power-down reset.
--
Efficiency based on switching
and resistance losses.