Power Supply Fusing - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

Set Up
2.3.
The entire chassis is protected by CB1, a combination power switch and circuit breaker.
There will be either a 5A breaker or an 10A breaker (see section 3.4.). The Bus Power
Supplies are individually fused on the AC side of the circuit by F1 – F4 (see section 4.5.).
The fuses are located inside the DR300 on a fuse block mounted to the left side on the
bottom of the DR300 near the transformers. The right fuse is for Bus supply #1 and the
left fuse is for Bus supply #2. The value of these fuses can be found on the DR300 system
wiring drawing (see Chapter 4, Table 4-3).
WARNING
Besides the two Bus power supplies the DR300 contains a power supply that provides +5,
+12, -12 and +24 VDC. This supply is located on the right side of the DR300 and is not
user serviceable. Several re-settable fuses are located on the Rear Panel Interface board
for external +5V usage. These fuses do not require replacement, but are reset by turning
off power for approximately 30 seconds (remove shorts or overloads from +5V before
turning power on).
2-28
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DR300 Operation and Technical Manual

Power Supply Fusing

To minimize the possibility of electrical shock and bodily injury, ensure that all
electrical power switches are in the off position and disconnect main power.
Aerotech, Inc.