Voltage Selector Function; Table 4-1. Voltage Selector Switch Settings - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR300 Operation and Technical Manual
4.3.

Voltage Selector Function

The Soft-Start / Voltage Select Board contains four user settable switches (S1-S4) to
configure the controller for 100 VAC, 115 VAC, 200 VAC or 230 VAC input power. The
voltage selector can only be used with transformers designed to interface with this board.
The location of these switches is shown in Figure 4-1.
Procedure for setting AC voltage selector switches:
1.
Turn-off and disconnect all power from unit.
2.
Determine the AC line operating voltage that unit needs be set to (Nominal settings:
100VAC, 115VAC, 200VAC and 230 VAC).
3.
Use Table 4-1 to set all four of the voltage selector switches to the position indicated
for the desired operating voltage. See Figure 4-1 for additional information.
Example: For 230VAC Operation, Set: S1 to "DN" position, S2 to "UP"
position, S3 to "DN" position, and S4 to "UP" position.
Table 4-1.
Voltage Selector Switch Settings
AC Volts
S1
100 VAC
UP
UP
115 VAC
DN
200 VAC
230 VAC
DN
NOTE:
"UP" and "DN" refer to positions of S1-S4 shown in
The Voltage Selector can only be used with transformers designed to interface with
this circuit. This Voltage Selector function will not work with off-line supplies.
Damage to unit may result if this function is used improperly.
The Voltage Selector must be setup to match the AC line voltage. Damage to unit
may result if the Voltage Selector is set to a voltage that is different from the input
AC Line voltage.
Disconnect Mains power before opening chassis. Voltage selector settings must not
be changed with Mains power applied to unit.
Version 1.5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
S2
S3
S4
DN
UP
DN
UP
UP
UP
DN
DN
DN
UP
DN
UP
Figure 4-1.
Aerotech, Inc.
Soft-Start
WARNING
WARNING
4-3