Chapter 4: Soft-Start / Voltage Selector Board; Soft-Start / Voltage Selector Overview - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR300 Operation and Technical Manual

CHAPTER 4: SOFT-START / VOLTAGE SELECTOR BOARD

In This Section:

• Soft-Start / Voltage Selector Overview .................. 4-1

• Soft-Start Operation................................................ 4-2
• Voltage Selector Function ..................................... 4-3
• Connector Pinouts .................................................. 4-4
• Fuse Information..................................................... 4-5
4.1.
Soft-Start / Voltage Selector Overview
The Soft-Start / Voltage Selector Board is used to limit AC inrush current during turn-on
and selection of the AC line voltage. The Soft-Start / Voltage Select Board is shown
below.
UP
S1
F1
4ASB
DN
SWITCH SETTINGS
S1
S2
100VAC
UP
DN
115VAC
UP
UP
200VAC
DN
DN
230VAC
DN
UP
Figure 4-1.
Version 1.5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
UP
UP
S2
S3
F2
F3
4ASB
3ASB
DN
DN
WARNING: S1, S2, S3 AND
S3
S4
S4 MUST BE SET FOR THE
UP
DN
APPLIED AC POWER INPUT
VOLTAGE. SETTING S1-S4
UP
UP
DN
DN
INCORRECTLY MAY RESULT
DN
UP
IN DAMAGE TO UNIT.
Soft-Start / Voltage Select Board
Aerotech, Inc.
UP
S4
F4
3ASB
DN
Soft-Start
4-1