Remote Feature To Inverter Compatibility - Magnum Energy ME-ARC Series Owner's Manual

Advanced remote control
Hide thumbs Also See for ME-ARC Series:
Table of Contents

Advertisement

3.0 Setup

3.2 Remote Feature to Inverter Compatibility

The ME-ARC has many settings and is designed to work with the advanced
features in your Magnum inverter—and/or other Magnum devices (i.e., ME-
AGS-N or ME-BMK). The ME-ARC communicates with your inverter to allow the
set up and enabling of these advanced features. However, when the ME-ARC
is released with new software, some of the features and functionality in the
remote may not be available in an inverter or networked accessory that has
an earlier software level. In this case, the advanced setting is not recognized
and will not function. Use the steps below to help you determine which ME-
ARC (Revision 3.0) menus/features are compatible with your inverter.
1.
Go to:
http://www.magnumenergy.com/Service/Compatibility.htm
determine your inverter's compatibility level (L1, L2, L3 or L4).
2.
Use Table 3-1 to determine which ME-ARC 'features/settings' you want
to use and what inverter compatibility level is required (see the "Model/
Level Required" column in Table 3-1).
3.
If your inverter compatibility level is the same or greater than the level
required, your inverter can support the device setting/feature you want.
4.
If your inverter does not have the required compatibility level for a fea-
ture/setting you want, contact Magnum Energy for a software upgrade.
Info: This compatibility matrix is available online to download/
print as a single page document and to enter user settings.
http://www.magnumenergy.com/Service/Compatibility.htm.
Table 3-1, ME-ARC (Revision 3.0) Compatibility Matrix
FEATURES/SETTINGS
Main
Menu
Menu
Heading/Item
01 ACIn Control
02 CHG Control [5]
03 Gen Control
01A DC Volts
01 DC
01B DC Amps
Meters
01C Charge
Time
02A Output Volts
02B Output Hz
02C Load Amps
02 AC
02D Input Amps
Meters
02E Inv/Chg
[5]
Amps
02F Input AC
(AC1)
02G Input AC2
10
Selections/
Adjustments Range
Auto Connect
VDC Connect, Time
Connect, AC-In Disabled
SOC Connect
Multi-Stage, Force
Float, Restart Bulk
OFF, ON, AUTO
Read only display
Read only display
© 2012 Magnum Energy, Inc.
Model/
Default
Level
Setting
Required
≥Level 1
≥Level 3
Auto
[1]
Connect
≥Level 3 [1][6]
≥Level 4
Multi-
Stage
≥Level 1 [7]
OFF**
Read
≥Level 1
Only
≥Level 4
Read
Only
≥Level 4 [1, 3]
MSH-RE Models
to