3.0 Operation

3.0 Operation

Start-up

After Installing and connecting the MM Series remote control, the
remote should be tested to ensure it is functional.
1. Press the ON/OFF push-button located on the display panel.
Note: The ON/OFF control switch is a push-button switch which
functions by momentary pressing and releasing.
2. After pressing the ON/OFF switch, verify the INVERT indicator
(green LED) is on (solid or blinking) and the status indicator on the
MM Series inverter is also on.
3. Press the ON/OFF switch again to turn the inverter off and verify
the INVERT indicator on the remote and the status indicator on the
inverter both go off.
If the remote passes all the steps, the inverter is ready for use.
If the remote fails any of the steps fails, check all the connections at
both ends of the communications cable and ensure the inverter is
operational. If the FAULT indicator comes on, refer to the Trouble-
shooting section in the MM Series Inverters, Installation and Opera-
tion Guide to help clear the fault condition.

Factory Default Settings

Your MM Series inverter has many functions that have changeable
settings. These settings are preset and loaded by the inverter when
turned on. However, if the MM remote control is connected to the
inverter, the settings from the remote over-ride any default settings
in the inverter. The settings in the remote are saved in the remote's
non-volatile memory and will be used - even if DC power to the
inverter is lost - as long as the remote is connected. See Table 1 for
the inverter's default settings and the settings that are changed when
connected to the MM remote.

Table 1, Inverter and Remote Settings

Function
Search Watts
LowBatCutOut
Battery AmpHrs
Battery Type
Charge Rate
VAC dropout
Note: For more information on these settings, refer to the MM
Series Inverters, Installation and Operation Guide.
6
Inverter Settings
NA (MM612 / MM612G),
5W (all other MM Series)
10.0 VDC
400 AmpHrs
(Absorb Time = 120 minutes)
Flooded - Liquid Lead Acid
(Bulk = 14.6 VDC,
Float = 13.4 VDC)
100%
80VAC
Remote Settings
NA (MM612 / MM612G),
5W (all other MM Series)
10.0 VDC
400 AmpHrs
(Absorb Time = 120 minutes)
Flooded - Liquid Lead Acid
(Bulk = 14.6 VDC,
Float = 13.4 VDC)
100%
90VAC