The ME-ARC may only be used in life-support devices or systems with the express written ap- proval of Magnum Energy. Failure of the ME-ARC can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or sys- tem.
Magnum inverter/charger. This remote can be used on all Magnum inverter/charger models so there is no cross-platform confusion. The ME-ARC50 comes standard with a 50-foot, 4-conductor (twisted-pair) telephone cable and includes non-volatile memory (preserves adjustable settings, even if power to the remote or in- verter is removed).
Eight #8 x 3/4 Phillips screws • ME-ARC Owner’s Manual If items appear to be missing or damaged, contact your authorized Magnum Energy dealer or Magnum Energy. IMPORTANT: Save your proof-of-purchase as a record of your ownership; it is needed if the unit should require in-warranty service.
When the ME-ARC is first connected to an inverter, a power-up self test is initialized. During the self test, the LCD automatically displays in sequence: • “MAGNUM ENERGY Self Test”, then • “(C)2010-2013, Connecting to...”, and then •...
LECT knob until “PIN = 0000” displays (approximately 7 seconds). Enter a new PIN number. TECH: 06 Ext Control External Control is a read only menu. Magnum Energy has adopted an open protocol policy which allows certain functions of the inverter/charger to be controlled externally—such as with a third party communications device.
Unknown Mode ## – This status message displays when the inverter/charger has sent an operational status code that the ARC remote does not identify. Remedy: Call Technical Support at Magnum Energy (425-353-8833) for assistance in identifying and understanding the actual fault status.
Page 60
Unknown Fault ## – This fault message displays when the inverter/charger has sent a fault code that cannot be identified by the remote. Remedy: Contact Technical Support at Magnum Energy for more information or assistance in identifying the actual fault status.
Page 61
(listen and make sure you hear an audible “click” from the connectors at both inverters). Info: This fault has been known to occur when a Magnum Energy accessory is plugged into the Stack Port, but the installation is not using multiple inverters in a stacked confi...
Factory Fault – The BMK has lost its factory-set internal calibration reference. Remedy: Reset the battery monitor by removing all power from the BMK. If the fault remains or returns after resetting, the BMK will require repair at a Magnum Energy factory service facility.
Using an ACLD: Setup/Monitoring Using an ACLD This section discusses how to confi gure and monitor Magnum’s AC Load Diversion controller (ACLD) using the ME-ARC remote. Refer to your ACLD owner’s manual (PN: 64-0062) for addi- tional information on setup and operation procedures. IMPORTANT: An ACLD must be connected and communicating with the ME-ARC in order to monitor its operation.
Remedy: This fault requires a reset of the ACLD. Press the ON/OFF switch on the side of the ACLD controller to remove power to the unit, and then press the ON/OFF switch again to restore power. If fault recurs, contact Magnum Energy for service. •...
Page 130
Using a PT Controller: Troubleshooting • FET Overtemp-PT – The internal FETs (Field Effect Transistors) have exceeded their safe temperature operating range (≥85˚C/185˚F). Remedy: If this fault happens often, ensure the controller is not in a hot area, has proper ventilation, and the cooling fans inside are working. Note: This fault automatically clears and the unit resumes operation when the FET temperature has cooled down to 83°C/181°F or below.
4. If your inverter does not have the required compatibility level for a feature/setting you want, contact Magnum Energy for a software upgrade. Info: The ME-ARC compatibility matrix below is also available online to download or to print as a single page document.
Page 134
Appendix A – ME-ARC Compatibility Matrix Features/Settings Model/ Level Default Menu Selections/ Main Menu Required Heading/Item Adjustments Range Now: Read Only 07F Power to Bat Life: displays Reset: 07 PT 07G Ground Fault Read Only display Read ≥Level 1 Meters Only 07H PT Data PT Data...
Page 136
Appendix A – ME-ARC Compatibility Matrix Features/Settings Model/ Level Default Menu Selections/ Main Menu Required Heading/Item Adjustments Range OFF, Start Gen SOC = 20-99% ≥Level 1 04D Gen Run SOC Stop Gen SOC = 21-100% Start = OFF, Ext Input, 65-95F (18-35C) 04E Gen Run Temp ≥Level 1...
Appendix B – Warranty & Service Limited Warranty Magnum Energy, Inc., warrants the ME-ARC to be free from defects in material and workmanship that result in product failure during normal usage, according to the following terms and conditions. 1. The limited warranty for this product extends for a maximum of 12 months from the product’s original date of purchase.
Page 139
Magnum Energy, Inc. 2211 West Casino Rd. Everett, WA 98204 Phone: 425-353-8833 Fax: 425-353-8390 Web: http://magnumenergy.com ME-ARC Owner’s Manual (PN: 64-0030 Rev C)