Operation; Start-Up; Factory Default Settings; Table 1, Inverter And Remote Settings - Magnum Energy MM-R Owner's Manual

Hide thumbs Also See for MM-R:
Table of Contents

Advertisement

3.0 Operation

3.0 Operation

Start-up

After installing and connecting the MM-R/MM-RC remote controls,
the remote should be tested to ensure it is functional.
1. Press the ON/OFF push button located on the display panel.
Info: The ON/OFF control switch is a push button switch
which functions by momentary pressing and releasing.
2. After pressing the ON/OFF switch verify the INVERT indicator
(green LED) is on (solid or blinking), and the status indicator on the
inverter is also on.
3. Press the ON/OFF switch again to turn the inverter off, and then
verify the INVERT indicator on the remote and the status indicator
on the inverter both go off.
If the remote passes all the above steps, it's ready for use.
If the remote fails any of the steps, check all the connections at
both ends of the communications cable and ensure the inverter is
operational. If the FAULT indicator comes on, refer to the Trouble-
shooting section in the MM/MM-AE Series inverters' Owner's Manual
to help clear the fault condition.

Factory Default Settings

Your MM/MM-AE Series inverter has many functions that have
changeable settings. These settings are preset and loaded by the
inverter when turned on. However, if the MM remote control is con-
nected to the inverter, the settings from the remote override any
default settings in the inverter. The settings in the remote are saved
in the remote's non-volatile memory, and will be used — even if DC
power to the inverter is lost — as long as the remote is connected.
See Table 1 for the inverter's default settings and the settings that
are changed when connected to the MM remote.

Table 1, Inverter and Remote Settings

Function
Search Watts
5W (all other MM & MM-AE Series)
LowBatCutOut
Battery AmpHrs
(Absorb Time = 120 minutes)
Flooded - Liquid Lead Acid
Battery Type
Charge Rate
VAC dropout
Info: For more information on these settings, refer to
the MM/MM-AE Series inverters' Owner's Manual.
6
Inverter Settings
NA (MM612),
10.0 VDC
400 AmpHrs
(Bulk = 14.6 VDC,
Float = 13.4 VDC)
100%
80 VAC
Remote Settings
NA (MM612),
5W (all other MM & MM-AE Series)
10.0 VDC
200 AmpHrs
(Absorb Time = 120 minutes)
AGM2
(Bulk = 14.5 VDC,
Float = 13.5 VDC)
100%
80 VAC