7.0 Using an AGS Module
To manually stop the generator:
1.
Press the CTRL button.
2.
Turn the SELECT knob to the 03 Gen Control menu.
3.
Press the SELECT knob. The Set Gen Control menu displays with an arrow
to the right of the current setting.
4.
Turn the SELECT knob to the OFF setting.
5.
Press the SELECT knob again to select this setting. The selection arrow
appears to the right of the screen. The generator should stop at this time.
If the generator does not stop as expected, refer to Section 7.8 "ME-AGS-N
Remote Troubleshooting" in this manual.
To manually start the generator and have it automatically stop:
1.
Press the CTRL button.
2.
Turn the SELECT knob to the 03 Gen Control menu.
3.
Press the SELECT knob. The Set Gen Control menu displays with an arrow
to the right of the current setting.
4.
Turn the SELECT knob to the ON setting.
5.
Press the SELECT knob again to select this setting. The selection arrow
appears to the right of the screen. The generator should start at this time.
Once the generator is running, rotate the SELECT knob to AUTO (under the
03 Gen Control menu), and then press the SELECT knob to select this setting.
If the generator does not start or stop as expected, refer to Section 7.8 "ME-
AGS-N Remote Troubleshooting" in this manual.
Note: When the generator is manually started, but then changed to autos-
top, the SETUP: 04A Gen Run VDC settings are used to determine when the
generator will autostop. If the SETUP: 04A Gen Run VDC is set to OFF, the
Start/Stop Volts Delay and Stop Gen Volts values that were entered prior to
selecting OFF will still be used to autostop the generator.