3.0 Setup
3.2

Remote Feature to Inverter Compatibility

The ME-RC has many settings and is designed to work with the standard
features in your Magnum inverter—and/or other Magnum devices (i.e., ME-
AGS-N or ME-BMK). The ME-RC communicates with your inverter to allow
the set up and enabling of these standard features. However, when the ME-
RC is released with new software, some of the features and functionality in
the remote may not be available in an inverter or networked accessory that
has an earlier software level. In this case, the setting is not recognized and
will not function. Use the steps below to help you determine which ME-RC
(Revision 2.8) menus/features are compatible with your inverter.
1.
Go to:
http://www.magnumenergy.com/Service/Compatibility.htm
determine your inverter's compatibility level (L1, L2, L3, or L4).
2.
Use Table 3-1 to determine which ME-RC features/settings you want to
use, and what inverter compatibility level is required (see the "Inverter
Model/Level Required" column in Table 3-1).
3.
If your inverter compatibility level is the same or greater than the level
required, your inverter can support the setting/feature you want.
4.
If your inverter does not have the required compatibility level for a fea-
ture/setting you want, contact Magnum Energy for a software upgrade.
Info: The ME-RC compatibility matrix below is also available online to
download/print as a single page document and to enter user settings.
http://www.magnumenergy.com/Service/Compatibility.htm.

Table 3-1, ME-RC (Revision 2.8) Compatibility Matrix

FEATURES/SETTINGS
Menu
Menu Item
Heading
Shore Max
01 AGS
Control
02 AGS
Status
03 Run
Run Time=
Time Hour
04 Start
Start Temp=
Temp F
05 Start
Start VDC=
Volts
06 Set
Time
07 Quiet
Time
9
Selections/
Adjustments Range
5 - 60A
OFF, Enable, Test, Enable
AGS=
w/QT (Set Time)
AGS:
Read only display
0.5 - 25.5 Hours
OFF, Ext Input, 65 - 95F
OFF, 10.0 - 12.2*
Hour=
01:xxx-12:xxx
Minute=
xx:00x-xx:59x
AM-PM=
xx:xxA-xx:xxP
OFF,
Quiet=
9PM- (7AM/8AM/9AM),
(10PM/11PM) - 8AM
Inverter
Model/
Level
Required
Level 1
[1]
Level 1
Level 1
Level 1
Level 1
Level 1
Level 1
Level 1
©2013 Magnum Energy, Inc.
to
Default
Setting
30A
OFF**
Read Only
2.0 Hrs
OFF
11.0
12:00A
OFF