3.0 Setup

3.3.5 TECH Button and Menus

The TECH menu button provides access to selections that are used to assist
service technicians in troubleshooting. It provides access to system informa-
tion along with a selection that allows all system settings to be returned to
their original factory default values.
LCD
Display
Top line shows
current TECH menu
heading
TECH
01 Temperatures
Press SELECT
Press
Bottom line shows
current TECH menu
selection/current setting
01 Temperatures
Press SELECT
...

Figure 3-7, TECH Button and Menus

TECH: 01 Temperatures

Displays the various temperatures measured throughout the system. Rotate
the SELECT knob to scroll through these temperature readings. The following
temperature displays are available:
Batt Sensor – Displays the temperature of the inverter's Battery Temp
Sensor (BTS) that is connected to the battery bank.
Transformer – Displays the temperature of the main power transformer
inside the inverter.
Transistors – Displays the temperature of the inverter's FETs (Field Effect
Transistors).
AGS – Displays the temperature of the AGS Temp Sensor that is plugged
into the REMOTE port on the ME-AGS-N module.
Info: The temperatures are displayed in Fahrenheit or Celsius, as
selected in the SETUP button's 01E Temp Display menu.
38
TECH Button
To select the next
04 Fault History
06 Ext Control
Press SELECT
...
© 2012 Magnum Energy, Inc.
TECH menu
Rotate to
desired
selection:
07 Load Defaults
Press SELECT
Press SELECT
Rotary
SELECT
Knob
Press to
select TECH
menu