Remote Feature To Inverter Compatibility; Table A-1, Me-Arc (Version 4.0) Compatibility Matrix - Magnum Energy ME-ARC50 Owner's Manual

Me-arc series. advanced remote control. version 4.0 or higher: with ags, bmk, acld, and pt info
Hide thumbs Also See for ME-ARC50:
Table of Contents

Advertisement

Appendix A – ME-ARC Compatibility Matrix
A-1

Remote Feature to Inverter Compatibility

The ME-ARC has many settings and is designed to work with the advanced features in your Mag-
num inverter—and/or other Magnum devices (i.e., ME-AGS-N, ACLD-40, PT-100 or ME-BMK).
The remote communicates with your inverter to allow the set up and enabling of these advanced
features. However, when the ME-ARC is released with new software, some of the features and
functionality in the remote may not be available in an inverter or networked accessory that has
an earlier software level. In this case, the advanced setting is not recognized and will not func-
tion. Use the steps below to help you determine which ARC (Version 4.0) menus/features are
compatible with your inverter.
1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter's com-
patibility level (L1, L2, L3, or L4).
2. Use Table A-1 to determine which ME-ARC 'features/settings' you want to use and what in-
verter compatibility level is required (see the "Model/Level Required" column in Table A-1).
3. If your inverter compatibility level is the same or greater than the level required, your in-
verter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want,
contact Magnum Energy for a software upgrade.
Info: The ME-ARC compatibility matrix below is also available online to download or
to print as a single page document. To download or to print, go to:
http://magnumenergy.com/inverter-compatibility/

Table A-1, ME-ARC (Version 4.0) Compatibility Matrix

Main
Menu
Heading/Item
01 ACIn Control
02 CHG Control
03 Gen Control
04A PT CHG Ctrl
04B PT Aux Relay
04 PT
Ctrl
Control
04C PT Alarm Control OFF, VDC, FAULT, ON
04D PT MPPT Sweep
01A DC Volts
01 DC
Meters
01B DC Amps
02A AC Output
02B Load Amps
02 AC
Meters
02C Input Amps
02D Inv/Chg Amps
Page 125
Features/Settings
Menu
Adjustments Range
Auto Connect
VDC Connect, Time Connect,
ACIn – Disabled
SOC Connect
Multi-Stage, Start Float, Start
Bulk
OFF, ON, AUTO
Multi-Stage, Charger Off, Start
Float, Start Bulk, Start EQ
DISENGAGE, VDC, FAULT,
ENGAGE
5 Min, 15 Min, 1 Hour,
Fixed Sweep
Read Only display
Read Only
Selections/
Model/
Level
Default
Required
≥Level 1
≥Level 3
Auto
[1]
Connect
≥Level 3 [1][6]
Multi-
≥Level 4
Stage
≥Level 1 [7]
OFF**
Multi-
Stage
DISEN-
GAGE
≥Level 4
OFF
15 Min
Sweep
Read
≥Level 1
Only
≥Level 4
Read
Only
≥Level 4 [3]