2.0 Installation

2.4.2 Surface Mount Installation Procedure

To surface mount, you must use the supplied bezel (Figure 2-4).
Info: The bezel has tabs at the bottom and side that are made with
thinner material (Figure 2-4). They can be cut or broken out to allow
the cable to be routed downward or to the side (Figure 2-6).
1.
Using the bezel as a template, mark on the wall the location of the four
bezel mounting screws, and then drill pilot holes for the #8-32 screws.
2.
Cut/break the appropriate tab for the planned route of the remote cable.
3.
Pull the cable thru the bezel and place the bezel side with the removed
tab over the cable against the wall.
4.
Position the bezel over the drilled mounting holes, and then screw the
bezel to the wall using the supplied Phillips screws (Figure 2-6).
5.
Route the other end of the cable to the inverter/charger, and then plug
it into the inverter's RJ11 REMOTE port (blue label)— inverter has DC
power, but is OFF. See Figure 2-2.
6.
Take the other end of the cable and while plugging it into the back of
the ME-ARC, view the remote's display to ensure the Power-up Self Test
initiates (see Section 2.5).
7.
If the self test is successful, secure the ME-ARC to the bezel using four
of the supplied Phillips screws. If the self test is unsuccessful, refer to
the Section 6.0 "Troubleshooting".

Figure 2-6, Surface Mounting the ME-ARC using the Bezel

6