Figure 3-13, TECH Menus

 Defaults: This menu restores all settings on the ME-MR (and in the in-
verter/charger) to the original factory default settings. To restore, press
and hold the SAVE/HOLD button for 5 seconds (see Figure 4-1). After
the default settings have been restored, the display will show "Loaded".
The ME-MR factory defaults are listed in Table 3-4.

Table 3-4, ME-MR's Inverter/Charger Default Settings

Menu
AC In
Search Watts
Battery Amp-Hours
Battery Type
Charge Rate
Low Battery Cut Out
Low VAC Dropout
Power Save
Equalize
Charger Standby
Power On
TECH: SETUP
©2013 Magnum Energy, Inc.
Press the ON/OFF button to
to view TECH menus
TECH
Press ON
TECH menus are "read only"
displays, no changes can be
made to these screens*/**
FET Temp
xx C
xx C
Ext Ctrl
SETUP**
Lock
Default Setting
AC IN = 30 Amps
SEARCH = 5 Watt
BAT AHRS = 400 AH
(Absorb Time = 90 min.)
BAT TYPE = Flooded
CHG RATE = 100%
LBCO = 10 VDC (12-volt models),
20 VDC (24-volt models),
40 VDC (48-volt models)
VAC DROP = 80 VAC (150 VAC for export)
PWR SAVE = On (15 min.)
EQUALIZE = Disabled
CHARGER = No AC In
(Charger Standby is off, will automatically
charge when AC is connected)
POWER ON = Norm