3.0 Setup
Table 3-1, ME-ARC Compatibility Matrix (cont.)
FEATURES/SETTINGS
Menu
Main
Heading/
Menu
Item
02E AC-In
02
SOC
Invert
Setup
02F Power Up
(cont.)
Always
03A AC Input
Amps
03B Battery
Type
03C Max
Charge Rate
03
Char-
ger
03D VAC
Setup
Dropout
03E Absorb
Done
03F Max
Charge Time
03G Final
Charge Stage
04A Gen Run
VDC
04
04B Gen Run
AGS
Time
Setup
04C Gen Run
Amps
12
Selections/
Adjustments Range
Connect SOC= 20-98%
Disconnect SOC= 21-100%
ON, OFF
AC/AC1 Input= 5-60A
AC2 Input= 5-60A
Gel, Flooded, AGM, AGM2
Absorb (12.0-16.0)*
Float (12.0-16.0)*
EQ (12.0-16.0)*
0-100%
AC/AC1 Input= 60-100
VAC, UPS Mode
AC2 Input= 60-100 VAC
110-190 VAC, UPS Mode
Time= 0.1-25.5 Hrs
Amps= 0-150 ADC
SOC= 50-100%
0.0-25.5 Hrs
Multi, Float, Silent
Start Gen Volts= 9.0-15.9*
Start Volts Delay= 0-127
sec, 1-127 min
Stop Gen Volts= 9.1-
16.0*, Float
Stop Volts Delay=0-127
sec, 1-127 min
OFF, ON= Start Gen
Time= 12:00A-12:00P
Stop Gen Time= 12:00A-
12:00P
Start Gen AC Amps= OFF,
5-60A
Start Amps Delay= 0-127
sec, 1-127 min
Stop Gen AC Amps=
5-60A
Stop Amps Delay= 0-127
sec, 1-127 min
© 2012 Magnum Energy, Inc.
Model/
Default
Level
Setting
Required
50%
≥Level 3
[6]
100%
Always
≥Level 1
OFF
≥Level 1 [1]
30A
MSH-RE Models
20A
≥Level 1
Flooded:
14.6*
≥Level 3
13.4*
15.5*
≥Level 3
100%
U.S. Models
80 VAC
MSH-RE Models
75 VAC
Export models
150 VAC
≥Level 4 [4]
2.0 Hrs
≥Level 4 [5]
≥Level 4 [5] [6]
12.0
≥Level 4 [5]
Hrs
≥Level 4 [5]
Multi
11.5
120 Sec
≥Level 1
14.4
120 Sec
OFF
≥Level 1
OFF
≥Level 4