Test Results Parameters Table—(TestResultsParameters)
This table contains the test parameters used at the time of testing and is associated with the TestResults records by
the test_resultno field.
Table 37: Test results parameters table field descriptions.
Field name
test_resultno
test_mode
temp_enabled
resist_enabled
Meg-Ohm_enabled
pi_enabled
HiPot_enabled
prgHiPot_enabled
surge_enabled
Table 38: Test results parameters table; temperature test parameters field descriptions.
Field name
temp_isAuto
temp_degF_C
Table 39: Test results parameters table; resistance test parameters field descriptions.
Field name
resist_no_leads
resist_deltaR_enabled
resist_ deltaR_maxpercent
resist_external_enabled
resist_isAuto
resist_4lead_test_enabled
resist_correct_to_temp_
enabled
resist_temp_correct_to
resist_temp_correct_factor Double
resist_target_coilRes_
enabled
resist_target_coilRes
resist_target_coilRes_
tolerance
www.megger.com
Type
Description
Long integer
Foreign key automatically generated in the TestResults Table.
Text (15)
Will contain one of the following values AUTOMATIC,
SEMIAUTOMATIC, MANUAL, or UNKNOWN.
Yes/No
Temperature test: 1=on; 0=off.
Yes/No
Resistance test: 1= on; 0=off.
Yes/No
Meg-Ohm test: 1=on; 0=off.
Yes/No
PI test: 1=on; 0=off.
Yes/No
HiPot test: 1=on; 0=off.
Yes/No
Step Voltage Test enabled: 1=on; 0=off.
Yes/No
Surge test: 1=on; 0=off.
Type
Description
Yes/No
1=Manual; 0=Automatic.
Yes/No
1=F degrees; 0=C degrees.
Type
Description
Short integer
# of leads (2 or 3) Used also in surge.
Yes/No
1=delta R used in pass/fail; 0=Not used.
Short integer
Max difference in percent.
Yes/No
Always false 0=No external testing.
Yes/No
1=Automatic; 0=Manual
Yes/No
1=4 lead test enabled; 0=4 lead test disabled (Only disabled at
this time)
Yes/No
Correct resistance 1=Yes; 0=No.
Short integer
Defines the value that the temperature will be corrected to.
Default 234.5 for copper.
Yes/No
1=Coil resistance checking enabled;0=not enabled.
Double
Coil resistance to compare tested value with.
Long integer
Tolerance set for target coil resistance.