Surge Test Results Table-(Surgewaveform) - Megger Baker AWA-IV User Manual

Static motor analyzer
Hide thumbs Also See for Baker AWA-IV:
Table of Contents

Advertisement

Surge Test Results Table—(SurgeWaveform)
The SurgeWaveform table contains a record for a test result. After a surge test has been performed, a record that
contains the motor_key and same test_result for one test is added to the table. This record contains all three surge
tests for a three-phase motor.
Table 36: Detailed surge test results.
Field name
test_rsultno
motor_key
waveFormatVr
xscale
yscale
microSecPerPnt
voltsPerPnt
wave1Full
wave1Mid
wave1Min
wave1PrevFail
wave1ppEAR
wave2Full
wave2Mid
wave2Min
wave2PrevFail
wave2ppEAR
wave3Full
wave3Mid
wave3Min
wave3PrevFail
wave3ppEAR
158
Baker AWA-IV 71-015 EN V16 User Guide
Type
Description
Long integer
Test result number (unique key ties to other test results).
Long integer
Motor identification key.
Double
Version of waveform record.
Short integer
Scale index for the x-axis (micro seconds per division).
Short integer
Scale index for the y-axis (volts per div).
Double
Micro seconds per point (Not used ).
Double
Volts per point (Not used at this time).
Full waveform for lead 1.
Middle waveform for lead 1.
Minimum waveform for lead 1.
Wave form before the failed waveform for lead 1.
Pulse-to-Pulse EAR for lead 1.
Full waveform for lead 2.
Middle waveform for lead 2.
Minimum waveform for lead 2.
Wave form before the failed waveform for lead 2.
Pulse-to-Pulse EAR for lead 2.
Full waveform for lead 3.
Middle waveform for lead 3.
Minimum waveform for lead 3.
Wave form before the failed waveform for lead 3.
Pulse-to-Pulse EAR for lead 3.
www.megger.com