Table 31: PI test results.
Field name
pi_status
pi_whyFailed
pi_voltage
pi_da_ratio
pi_ratio
Table 32: HiPot test results.
Field name
HiPot_status
HiPot_whyFailed
HiPot_voltage
HiPot_current
HiPot_Meg-Ohm
HiPot_IR_at_40C
Table 33: DC High Potential (HIPot) test results.
Field name
surge_status
surge_whyFailed
surge_peak_volt1
surge_peak_volt2
surge_peak_volt3
surge_ear1_2
surge_ear1_3
surge_ear_2_3
Memo Table—(Memo)
This table contains the memo if any that a user can fill out per test result.
Table 34: Memo table field descriptions.
Field name
Test_resultno
motor_key
memo
www.megger.com
Type
Description
Text (8)
Contains the status of the test, PASS or FAIL if a test has been
performed or blank if no PI test has been conducted. (DA Only
DPASS/DFAIL.)
Text (25)
Reason why motor failed (if it failed).
Short integer
Test voltage for PI test.
Double
3-minute resistance value divided by 30-second resistance
value.
Double
10-minute resistance value divided by 1-minute resistance
value.
Type
Description
Text (8)
Contains the status of the test, PASS or FAIL if a test has been
performed or blank if no HiPot test has been conducted.
Text (25)
Reason why motor failed (if it failed).
Long integer
Voltage at the end of test.
Double
Current at the end of test.
Long integer
Meg-Ohm value = voltage/current.
Long integer
Meg-Ohms (insulation resistance) at 40 °C.
Type
Description
Text (8)
Contains the status of the test, PASS or FAIL if a test has been
performed or blank if no surge test has been conducted.
Text (25)
Reason why motor failed (if it failed).
Short integer
Peak voltage reached for lead 1.
Short integer
Peak voltage reached for lead 2.
Short integer
Peak voltage reached for lead 3.
Short integer
Error Area Ratio lead 1 to lead 2.
Short integer
Error Area Ratio lead 1 to lead 3.
Short integer
Error Area Ratio lead 2 to lead 3.
Type
Description
Long integer
Foreign key used to link test result records.
Long integer
Motor key Identification key.
Memo
Memo field type containing the user entered text.