Nameplate Table—(MotorID)
The MotorID table contains the nameplate information for each motor added to the database. There is only one
motor record per motor. The motor_key is the primary keyed field. It is automatically generated when a new motor
is added. The Motor ID field is a unique identifier that the user gives each motor.
Table 26: Field name descriptions.
Field name
motor_key
tree_level_1
tree_level_2
tree_level_3
custom_string
motor_id
manuf
manuf_type
manuf_date_code
model
sn
hpkw
rpm
voltage_rating
voltage_operating
amps_rating
amps_operating
frame
insulation_class
lockec_rotor_current
locked_rotor_code
service_factor
enclosure
freq_hz
NEMA_design_code
NEMA_nom_efficiency
max_ambient_temp
duty_cycle
user_defined_description
winding_config
152
Baker AWA-IV 71-015 EN V16 User Guide
Type
Description
Long integer Automatically generated number used as the primary key.
Text (40)
First level used in the tree view. Motor location 1 user defined field label,
defaults to Location.
Text (40)
Second level used in the tree view. Motor location 2 user defined field
label, defaults to Building.
Text (40)
Third level used in the tree view. Motor location 3 user defined field
label. Not used by default. To make this field show up in the interface,
assign a label for it in the DatabaseInfo table (via View  Options 
Changeable Labels.
Text (40)
General purpose description field; not related to motor location. Not
used by default. To make this field show up in the interface, assign a
label for it in the DatabaseInfo table (via View  Options  Changeable
Labels.
Text (30)
User entered Motor Identification value. It must be unique.
Text (25)
Manufacturer of the motor.
Text (25)
NEMA MG 1 requires manufacturer's type but may vary depending on
manufacturer.
Text (16)
Manufacturer's nameplate date.
Text (25)
Manufacture's Identification of model type.
Text (25)
Manufacture's serial number.
Single
Nameplate horse power or kilowatts.
Single
Revolutions per minute (RPM).
Text (16)
Nameplate voltage ratings.
Single
Name Plate Voltage used as a Voltage Class.
Text (16)
Nameplate current (amps) ratings.
Single
Operating current (amps).
Text (16)
Frame type code indicating dimensions.
Text (8)
Locked rotor current in amps.
Single
Locked rotor current in amps.
Text (4)
A letter code that groups motors based on KVA/hp. (KVA code)
Single
Factor when multiplied by hp, gives the allowable hp loading.
Text (16)
Classifies the motor as to its degree of protection from the environment
and method of cooling.
Long integer Input frequency usually 50 or 60 Hz.
Text (4)
NEMA codes assigned to define torque and current characteristics of the
motor.
Short
This represents an average efficiency of a large population of like motors.
Single
The maximum ambient temperature at which the motor can operate
and still be within the tolerance of the insulation class at the max
temperature rise in C.
Text (16)
Defines the length of time during which the motor can carry its
nameplate rating safely.
Text (64)
User defined motor description field.
Text (8)
Wye or delta winding configuration.