Baker Awa-Iv 6 Kv Model Distinctions - Megger Baker AWA-IV User Manual

Static motor analyzer
Hide thumbs Also See for Baker AWA-IV:
Table of Contents

Advertisement

Item
Description
12
Test leads 1–3 select buttons.
13
High-voltage test lead, black, ground.
14
High-voltage test leads—The Baker AWA-IV uses high-voltage test leads for surge, Baker
ZTX, and DC testing. Three test leads (red) and a ground lead (black) are provided for motor
test connections. Both sides of the connection clips must be in contact with the terminal of
the motor being measured. You must keep the leads clean and dry for best measurement
performance.
15
Resistance leads—For the 12 kV models, three test leads with no ground lead are used for
low-voltage testing. The clips and cord color can vary depending on the design. AWAIV 6 kV
models do not have this set of leads.
CAUTION: The test leads have exposed metal areas. Do not touch the leads while tests are running. Always ensure
that the test leads are not placed in proximity to the frame or ground potential.

Baker AWA-IV 6 kV Model Distinctions

The AWA-IV 6 KV model differs from the AWA-IV 12 kV with respect to test leads and procedures for use.
The AWA-IV 6 kV analyzer uses only one set of leads for both high- and low-voltage testing; it does not include a
separate set of low-voltage resistance test leads.
The clips are currently rated for 48 volts. Ensure that the clips are not placed in proximity to the frame or other
ground potential.
www.megger.com
Fig 5: AWA-IV 6 kV; high voltage leads only.