Megger Baker AWA-IV User Manual page 173

Static motor analyzer
Hide thumbs Also See for Baker AWA-IV:
Table of Contents

Advertisement

Table 43: Test results parameters table; Surge test parameters field descriptions.
Field name
surge_test_voltage
surge_no_leads
surge_ramp_rate
surge_pulses
surge_time_scale
surge_volts_scale
surge_PauseBetweenLeads Yes/No
surge_zero_enabled
surge_zero_percent
surge_EAR_enabled
surge_EAR_percent
surge_ppEAR_enabled
surge_ppEAR_percent
surge_refEAR _percent
surge_refwave_test_key
surge_PowerPack_enabled Yes/No
Table 44: Test results parameters table; additional fields descriptions.
Field name
surge_AT101_enabled
motor_voltage_class
temp_RH_enabled
HiPot_rampVTest_enabled
www.megger.com
Type
Description
Short integer
Target voltage of test.
Short integer
Number of leads: 2 or 3.
Short integer
Ramp rate.
Short integer
Number of pulses surged at test voltage.
Short integer
Index indicating the time per division.
0 – 2.5 uS
1 – 5 uS
2 – 10 uS
3 – 25 uS
Short integer
Index indicating the volts per division.
0 – 250
1 – 500
2 – 1000
3 – 2000
4 – Auto scale
1=Yes pause; 0=No do not pause.
Yes/No
Zero tolerance error checking on/off.
Short integer
Zero tolerance percent.
Yes/No
EAR checking on or off.
Short integer
EAR error tolerance
Yes/No
Pulse to pulse EAR error checking enabled.
Short integer
Pulse to pulse EAR tolerance percent.
Short integer
EAR tolerance with reference wave.
Long integer
0=No reference waveform; if any other number then it is a key
to the ref waveform record in the RefSrgWaveform table.
1=PP enabled; 0=No PP
Type
Description
Yes/No
1=AT101 enabled; 0=Not enabled
Long integer
Voltage class of the Test ID used
Yes/No
1=Relative Humidity enabled; 0= Not enabled
Yes/No
1=Ramped Voltage Test enabled; 0= Not enabled
4 – 50 uS
5 – 100 uS
6 – 200 uS
7 – Auto scaling
w/power pack 1000
w/power pack 2000
w/power pack 4000
w/power pack 8000
161

Advertisement

Table of Contents
loading

Table of Contents