Ac Power Requirement; Ac Power Cord; Table 2-3 Power Requirement; Figure 2-10 Eth Lug - NEC SL1100 Hardware Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 1.0
The grounding cable is supplier-provided.(not attached to the system)
1.
Loosen the screw.
2.
Insert a grounding wire (user supplied).
3.
Tighten the screw.
4.
Connect the grounding wire to earth ground.
Proper grounding is very important to protect the system from external noise and
to reduce the risk of electrocution in the event of a lightning strike.
1.4.2

AC Power Requirement

A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for the KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Power Requirement
Power Consumption
Input Voltage (Rated Voltage)
Frequency
Phase and Wire
Ground Requirement
Feeding Voltage
AC Input I
KWh
BTU (KWh x 3413)
1.4.3

AC Power Cord

The AC power switch and AC power inlet are located at the left side of the KSU. The AC power cord is
connected to the AC inlet and the commercial AC power socket.
Do not plug-in AC power cord if the KSU Cover is removed.
Hardware Manual

Figure 2-10 ETH Lug

Table 2-3 Power Requirement

110VAC
120VAC
110 VAC@15 A
120 VAC@15 A
Main KSU = 128
Main KSU = 130
VA
VA
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
47 Hz - 63 Hz (Rated Frequency: 50/60 Hz)
Main KSU =
Main KSU =
1.16 A
1.08 A
Main KSU =
Main KSU =
0.128 KWh
0.130 KWh
Main KSU = 437
Main KSU = 444
BTU
BTU
220VAC
220 VAC@15 A
230 VAC@15 A
Main KSU = 154
Main KSU = 154
VA
VA
Single Phase, 2 Line + PE Type
No.14 AWG Copper Wire
SLT: 20 mA/ -27 V
Main KSU =
Main KSU =
0.70 A
0.67 A
Main KSU =
Main KSU =
0.154 KWh
0.154 KWh
Main KSU = 526
Main KSU = 526
BTU
BTU
SL1100
230VAC
240VAC
240 VAC@15 A
Main KSU = 156
VA
Main KSU =
0.65 A
Main KSU =
0.156 KWh
Main KSU = 532
BTU
2-7