Making WLAN Measurements
Troubleshooting WLAN Measurements
Troubleshooting WLAN Measurements
The following table provides some with descriptions you might encounter when
making WLAN measurements.
Table 2-7
Error
Messages
Numbers
-221
Setting Conflict
-224
Illegal Parameter
215
Sync error; Preamble not found
217
Demod error; Invalid packet type
217
Demod error; Acq time too short
159
Settings Alert; Parm/data mismatch
For more information on error messages see Instrument Messages.
Keysight WLAN Measurement Guide
Notes
The parameter setting is not available for current
standard.
The parameter setting is not available for current
settings.
The preamble code is not detected.
Packet type detected is not recognized.
Not an entire Payload is captured, that is, the acquisition
time is too short.
The actual captured data length is not long enough, or,
the offset from TxFrequency to center frequency is not an
integer multiple of 1 MHz.
85