CVLAN and DLG System Administration
Diagnostics — Hardware Status
TN Code/Vintage:
TN801B
FW Version:
BOOT=777
RM Version:
BOOT=0.1.444
Alarm Count: 2
platform ambient temperature is high [WARNING]
voltage out of range [MINOR]
Temperatures:
actual
Temp1
99.71 deg F
Temp2
85.53 deg F
Voltages:
actual
+VEE
+12.18V
-VEE
-12.12V
+VCC
+5.11V
-VCC
-5.19V
3.3V
+3.32V
(EOF):
Screen 4-38. Hardware Status
This is a read-only screen that displays hardware status.
Field Name
TN Code/Vintage
FW Version
RM Version
Alarm count
NOTE:
Contact the TSC if any alarms exist or if any tests fail.
Use this screen as follows:
Press
4-64
Issue 3 May 2002
V1
APPL=15000
APPL=0.1.4
min
75.00 deg F
75.00 deg F
min
+11.40V
-12.60V
+4.75V
-5.25V
+3.13V
Description
Displays the MAPD (TN801B) board code and vintage as
reported by the DEFINITY system.
Displays the firmware version.
Displays the remote maintenance firmware version.
Displays the number of active alarms followed by a
description of each alarm and its severity.
to return to the Diagnostics menu.
RETURN
max
104.00 deg F
104.00 deg F
max
+12.60V
-11.40V
+5.25V
-4.75V
+3.46V