4.10 Reinstallation of displays

Note: Displays shall be reinstalled only when ECR is off and the external power adapter is disconnected.

4.10.1 Reinstallation of displays for the ECR Euro-500TX Handy

Reinstallation of the cashier display
1. Pull the middle cover from the bottom one (chapter 4.1).
2. Unplug the PR&DISP1 and PR&DISP2 connectors.
3. Remove the display visor and display paper cover.
4. Remove the adhesive from the display and display wiring and pull both out.
5. Mount the new display with the Interconnect PCB and fix the wiring and the display by adhesive.
6. Plug the connectors and assemble the middle cover back.
Reinstallation of the customer display
1. Remove the display visor and display paper cover.
2. Dismantle the defective customer display.
3. Mount the new display.
4. Place the display visor and paper cover back onto the middle ECR cover.
3
4
Index
Quantity
1
1
2
1
3
1
4
1
5
2
6
1
7
1

Tab. 4.10 Table of shown parts

Service manual
1
2

Fig. 4.14 Display reinstallation

Description
Display visor
Paper cover of displays
Alphanumeric cashier display
Intercon Euro 500TX Handy v1.2
Screw
10-segmented customer display
Distance washer 4 mm
© Elcom, s. r. o.
5
6
7